Technical Data

LF3, LC3, WCC, LC2, LCC

  • A350 LF3(d)
  • A 352 LC3(d)
  • A 216 WCC(a)
  • A 352 LC2(d)
  • A 352 LCC(e)
Notes:
  • a. Permissible but recommended for prolonged usage above about 800° F.
  • d.Not to be used over 650° F
  • e.Not to be used over 800° F
STANDARD CLASS
Temperature° F Working Pressure by Classes PSIG
150 300 400 600 900 1500 2500
-20 to 100 290 750 1000 1500 2250 3750 6250
200 260 750 1000 1455 2250 3750 6070
300 230 730 970 1410 2185 3640 5880
400 200 705 940 1410 2115 3560 5280
500 170 665 885 1330 1935 3325 5540
600 140 605 805 1210 1815 3025 5040
650 125 590 785 1175 1765 2940 4905
700 110 570 755 1135 1705 2840 4730
750 95 505 670 1010 1510 2520 4200
800 80 410 550 825 1235 2060 3430
850 65 270 355 535 805 1340 2230
900 50 170 230 345 515 860 1430
950 35 105 140 205 310 515 860
1000 20 50 70 105 155 260 430
SPECIAL CLASS
Temperature° F Working Pressure by Classes PSIG
150 300 400 600 900 1500 2500
-20 to 100 290 750 1000 1500 2250 3750 6250
200 290 750 1000 1500 2250 3750 6250
300 290 750 1000 1500 2250 3750 6250
400 290 750 1000 1500 2250 3750 6250
500 290 750 1000 1500 2250 3750 6250
600 290 750 1000 1500 2550 3750 6250
650 290 750 1000 1500 2550 3750 6250
700 275 710 950 1425 2135 3560 5930
750 240 630 840 1260 1890 3150 5250
800 200 515 685 1030 1545 2570 4285
850 130 335 445 670 1005 1670 2785
900 85 215 285 430 645 1070 1785
950 50 130 170 260 385 645 1070
1000 25 65 85 130 195 320 535

© right 2019 All Rights Reserved by Norflow Controls